Venus Versa Laser Multi-treatment System

$7.520

Included Handpieces & Usage:
HR690
HR650
SR515
SR580
Octipolar Handpiece
Diamondpolar Handpiece

Also Includes:
Handpiece Cases
Water Refill Kit
Operator Manual

Categories: , Tag:
Compare
Description

Venus Versa Laser Multi-treatment System

Get The Most In-demand Aesthetic Treatments In One Workstation
A versatile multi-application platform that provides the most popular, non-invasive aesthetic procedures, including photorejuvenation/photofacial and, hair removal (both of which are consistently in the top 5 minimally invasive treatments performed in the U.S. every year), acne treatment, skin resurfacing, body contouring, cellulite reduction, skin tightening and wrinkle reduction. It offers three unique technologies: Intense Pulsed Light (IPL) with SmartPulse™, NanoFractional Radio Frequency with SmartScan™, and Venus Concept’s proprietary (MP)2 technology (Multi-Polar Radio Frequency + Pulsed Electro Magnetic Fields). Venus Versa™ also offers the ability to use all three of these technologies in one TriBella™ treatment – a highly sought-after, tri-modality facial rejuvenation treatment with excellent results.

With the ability to meet today’s most in demand aesthetic treatments the Venus Versa™ is a sound investment for any clinic looking to expand its offerings with one workstation. Our versatile multi-treatment system allows you to offer a variety of services, increase patient demand and positively impact your ROI – all factors that will help your practice thrive for years to come.

Included Handpieces & Usage:
HR690
HR650
SR515
SR580
Octipolar Handpiece
Diamondpolar Handpiece

Also Includes:
Handpiece Cases
Water Refill Kit
Operator Manual

Venus Versa Laser Multi-treatment System

Dimensions: WxDxH(not packed)65x55x110cm (25.6×21.7×43.3in)
System Console Weight: 35kg (77.2 lbs)
Electrical Requirements:100-240 VAC, 16A, 50 – 60 Hz, Single Phase

Maximum RF Output Power:Diamondpolar:75 W
Octipolar:150 W
Diamondpolar:75 W
Octipolar:150 W
RF Output Frequency:1 MHz
Magnetic Pulse Frequency:15 Hz
Magnetic Field:Up to 15 Gauss

SR515 & SR580 IPL
Indicated Uses:515nm = Superficial Vascular and Pigmented Lesions; 580nm = Skin Rejuvenation
Wavelength:515 – 950nm, 580 – 950nm
Optical Energy:5 – 25J cmtwo
Pulse Duration:5 – 20ms
Spot Size:10mmx30mm
Pulse Repetition Rate:Up to 3Hz

HR650 & HR690 IPL
Indicated Uses:650nm & 690nm = Hair Removal
Wavelength:650 – 950nm, 690 – 950nm
Optical Energy:5 – 20Jcmtwo
Pulse Duration:20 – 50ms
Spot Size:10mmx30mm, XL:20mmx30mm
Pulse Repetition Rate:Up to 3Hz

Venus Versa combines three unique, highly effective technologies in one workstation for true versatility. The device can be customized to grow with your practice-start with one set of applicators and add more as you grow to maximize the treatments you can offer at your practice. Venus Versa™ can also be easily moved between treatment rooms, making it the ideal system for locations with limited space.

INTENSE PULSED LIGHT (IPL) WITH SMARTPULSE
Photorejuvenation/photofacial, acne treatment, hair removal
All IPL applicators include innovative SmartPulse technology to ensure precise and consistent energy delivery through advanced pulse optimization

Pulses of broad – spectrum light are selectively filtered and delivered into the skin, where it’s absorbed by target chromophores and transformed into therapeutic heat

For photorejuvenation photofacial, target chromophores are oxyhemoglobin for vascular lesions and melanin for pigmented lesions in the skin

For hair removal, target is melanin in the hair shaft

For dual – light acne treatment, blue light targets the porphyrian produced by Propionibacterium Acnes bacteria, leading to destruction of the bacteria, while the longer wavelength of red light controls inflammation and promotes faster healing

Real – time cooling system monitors the light guide temperature 1,000 times a second for unparalleled patient safety and comfort
NANOFRACTIONAL RADIO FREQUENCY (RF) WITH SMARTSCAN
Skin resurfacing

Designed to resurface the skin, which helps reduce the appearance of acne scars, traumatic scars, striae, rosacea, dyschromia, deep wrinkles, enlarged pores, and uneven skin texture and pigmentation

Tip is the largest spot size in the industry and delivers up to 700 pulses

Energy is distributed through small footprint per pin (150 x 20 microns) at variable energy densities in a single tip, reducing the risk of post -inflammatory hyperpigmentation (PIH) and leaving sufficient intact tissue in between, for faster wound healing, uniform post – treatment tissue appearance, and low downtime

SmartScan uses a unique algorithm and pattern selection technology that enables the operator to generate customized patterns for maximum flexibility and control during the treatment

(MP)2 TECHNOLOGY
Wrinkle reduction
Unique combination of Multi – Polar Radio Frequency (RF) and Pulsed Electro Magnetic Fields (PEMF)

Multi – Polar RF uses a complex algorithm to deliver homogeneous energy and volumetric heating to multiple tissue depths, allowing for quick and safe buildup of heat and easy maintenance of therapeutic temperature throughout the treatment

Effect of Multi – Polar RF is enhanced by PEMF, a non – thermal mechanism emitted through the applicator’s electrodes

Through synergistic (MP)2, RF heats and directly stimulates fibroblasts, while PEMF is known to promote angiogenesis and induce fibroblast proliferation through release of the growth factor FGF – 2, resulting in increased collagen synthesis

(MP)2 is therefore effective in remodeling of collagen, which reduces rhytides and wrinkles, and the creation of new capillaries, which renews blood supply

 